FR-UK 33 Series
Application: Computer Room, Data Centre, Precision Instrument, Intelligent Equipment
Features
- Online double conversion
- IGBT inverter and output isolation transformer
- 3 phases UPS allow 100% unbalance load
- Wide input voltage range
- DC cold start function
- Full protection function
- Intelligent RS232/RS485 communication port
- SNMP adapter (optional)
- Advanced no-master-slave parallel technology (optional)
- Intelligent battery monitor system – MMBM (optional)
| MODEL | FR-UK 3310 |
FR-UK 3320 |
FR-UK 3330 |
FR-UK 3340 |
FR-UK 3350 |
FR-UK 3360 |
FR-UK 3380 |
FR-UK 33100 |
FR-UK 33120 |
FR-UK 33160 |
FR-UK 33200 |
FR-UK 33300 |
FRUK33400 | FRUK33500 | |
| INPUT | Voltage(Vac) | 380/400 + 20% | |||||||||||||
| Rectifier Frequency |
40 - 65 | ||||||||||||||
| SYNC Frequency Tracking |
50/60 + 5% (+10% optional) | ||||||||||||||
| Phase | 3 0 4W+PE | ||||||||||||||
| OUTPUT | Capacity (KVA/W) | 10/8 | 20/16 | 30/24 | 40/32 | 50/40 | 60/48 | 80/64 | 100/80 | 120/96 | 160/ 128 |
200/ 160 |
300/ 240 |
400/320 | 500/400 |
| Phase | 3 0 4W+PE | ||||||||||||||
| Voltage(Vac) | L-N: 220/230 +1%, L-L:380/400+1% | ||||||||||||||
| Frequency(Hz) | 50 / 60 + 0.5% (battery mode) | ||||||||||||||
| Waveform | Pure Sine Wave, THD <3% at linear load | ||||||||||||||
| 3 Phases 100% Load Unbalance Voltage Stability |
≤2%, allow 100% unbalance | ||||||||||||||
| Overload | 110% load for 30 minutes, 125% load for 10 minutes, 150% load for 1 minute | ||||||||||||||
| BATTERY | Voltage (Vdc) | 12Vx29=348 | |||||||||||||
| BATT Type | External | ||||||||||||||
| Charger Current(A)Max |
10-40A setting | 20-80A setting | |||||||||||||
| Battery Selftesting | Automatically alarm and estimate battery status in battery abnormal status | ||||||||||||||
| OTHER | Maintenance Bypass | Yes | |||||||||||||
| Communication Interface | RS232/RS485 and dry contactor (MODBUS and SNMP adapter are optional) | ||||||||||||||
| Display | LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status | ||||||||||||||
| Alarm | Overload, abnormal AC input, low battery, UPS failure | ||||||||||||||
| Protection | Low battery, overload, over temperature, short circuit, output over voltage, output low voltage | ||||||||||||||
| Noise (dB) | <65 | ||||||||||||||
| Working Temperature | 0-40 | ||||||||||||||
| Relative Humidity | 0-95%, No condensation | ||||||||||||||
| Dimension (W x D x H) mm Standard/Long backup |
500x800x1180 | 800x800x1600 | 1000x800x1800 | 1800x 800x 2000 |
2200x1000x2000 | 4200x 1000x 2000 |
|||||||||
| Weight (kg) Standard/ Long backup |
195 | 240 | 290 | 450 | 470 | 490 | 690 | 725 | 775 | 905 | 1700 | 2350 | 2580 | 2800 | |