FR-UK 33A Series
Application: Computer Room, Data Centre, Precision Instrument, Intelligent Equipment
Features
- Online double conversion
- IGBT inverter and output isolation transformer
- 3 phases UPS allow 100% unbalance load
- Wide input voltage range
- DC cold start function
- Full protection function
- Intelligent RS232/RS485 communication port
- SNMP adapter (optional)
- Advanced no-master-slave parallel technology (optional)
- Intelligent battery monitor system – MMBM (optional)
| MODEL | FR-UK 3310A |
FR-UK 3320A |
FR-UK 3330A |
FR-UK 3340A |
FR-UK 3350A |
FR-UK 3360A |
FR-UK 3380A |
FR-UK 33100A |
FR-UK 33120A |
FR-UK 33160A |
FR-UK 33200A |
|
| INPUT | Voltage(Vac) | 208/220 + 20% (+ 25% optional) | ||||||||||
| Rectifier Frequency |
40 - 65 | |||||||||||
| SYNC Frequency Tracking |
50/60 + 5% (+10% optional) | |||||||||||
| Phase | 3 0 4W+PE | |||||||||||
| OUTPUT | Capacity (KVA/W) | 10/8 | 20/16 | 30/24 | 40/32 | 50/40 | 60/48 | 80/64 | 100/80 | 120/96 | 160/ 128 |
200/ 160 |
| Phase | 3 0 4W+PE | |||||||||||
| Voltage(Vac) | L-N: 120/127 +1%, L-L:208/220+1% | |||||||||||
| Frequency(Hz) | 50 / 60 + 0.5% (battery mode) | |||||||||||
| Waveform | Pure Sine Wave, THD <3% at linear load | |||||||||||
| 3 Phases 100% Load Unbalance Voltage Stability |
<2%, allow 100% unbalance | |||||||||||
| Overload | 110% load for 30 minutes, 125% load for 10 minutes, 150% load for 1 minute | |||||||||||
| BATTERY | Voltage (Vdc) | 12Vx16=192 | 12Vx29=348 | |||||||||
| BATT Type | External | |||||||||||
| Charger Current(A)Max |
10-40A setting | |||||||||||
| Battery Selftesting | Automatically alarm and estimate battery status in battery abnormal status | |||||||||||
| OTHER | Communication Interface |
RS232/RS485 and dry contactor (MODBUS and SNMP adapter are optional) | ||||||||||
| Maintenance Bypass | Yes | |||||||||||
| Display | LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status | |||||||||||
| Alarm | Overload, abnormal AC input, low battery, UPS failure | |||||||||||
| Protection | Low battery, overload, over temperature, short circuit, output over voltage, output low voltage | |||||||||||
| Noise (dB) | <65 | |||||||||||
| Working Temperature | 0-40 | |||||||||||
| Relative Humidity | 0-95%, No condensation | |||||||||||
| Dimension (W x D x H) mm Standard/Long backup |
500x800x1180 | 1000x800x1180 | 1200x800x1600 | 1800x800x1600 | 2700x800x2000 | |||||||
| Weight (kg) Standard/ Long backup |
300 | 327 | 340 | 606 | 611 | 640 | 990 | 1000 | 1200 | 1450 | 1700 | |